I'm trying out Oracle 10g. However after shutting down the instance and trying to start it up again, I encountered this error:

ORA-12528: TNS:listener: all appropriate instances are blocking new
connections

Could you please explain this and give me a solution for this error?

This is a known problem with Oracle 10g where a SHUTDOWN IMMEDIATE is followed by a STARTUP MOUNT. Perform another SHUTDOWN on the database and then issue a STARTUP. You should be able to connect to the database.